  ac-dc specification 300-600 watts industrial (sl) & medical (slm) versions output voltages from 12 v to 96 v power factor corrected remote on/off current share power fail signal overtemperature protection sl & slm series input input voltage 90-264 vac (125-360 vdc) input frequency 44-66 hz input current 300 w models: 4.4 a at 90 vac 1.8 a at 230 vac 600 w models: 8.9 a at 90 vac 3.5 a at 230 vac inrush current 100 a at 230 vac power factor 0.9 typical earth leakage current sl models: <2.5 ma at 264 vac/50 hz slm models: <100 ? at 264 vac/50 hz input protection 10 a hrc fuse output output voltage see table output voltage trim see table initial set accuracy 1% max minimum load no minimum load required start up delay 600 ms max start up rise time 150 ms max hold up time 18 ms min line regulation <0.5% v min to v max load regulation <2.0% for a 0-100% load change transient response 2% max deviation, recovery to within 0.25% in 1 ms for a 10% load change ripple & noise 1% pk-pk max, 20 mhz bw overvoltage protection 120% approx vnom overtemperature fitted to 600 w models only, protection recycle mains to reset overload protection 110% typical, constant current short circuit protection constant current temperature 0.02%/?c coefficient remote on/off output inhibited by shorting rof pin to 0 v current share allows up to 5 units to share within 5% xppower.com general efficiency 85% typical isolation 6000 vdc input to output (y caps disconnected) 2200 vdc input to ground 2200 vdc output to chassis switching frequency 30-35 khz pfc, 45-55 khz pwm signals ac ok - ttl compatible signal is high with reference to 0 v when ac is ok mtbf 105 khrs typical per mil-hdbk-217e at +20 ?c. consult office for each model environmental operating temperature -20 ?c to +70 ?c, derate from +40 ?c to 50% power at +70 ?c operating humidity 90% rh, non-condensing storage temperature -25 ?c to +85 ?c operating altitude 3000 m shock non operating. 100 mm drop on to chassis face vibration operating 5-50 hz 0.05 mm pk-pk, 50-100 hz 0.025 mm pk-pk airflow direction where fitted fans blow air into the unit emc & safety emissions en55022, level b conducted en55022, level a radiated harmonic currents en61000-3-2, class a voltage flicker en61000-3-3 esd immunity en61000-4-2, level 3 perf criteria a radiated immunity en61000-4-3, level 3 perf criteria a eft/burst en61000-4-4, level 3 perf criteria a surge en61000-4-5, level 3 perf criteria a conducted immunity en61000-4-6, level 3 perf criteria a dips & interruptions en61000-4-11, 30% 10 ms, 60% 100 ms, 100% 5000 ms perf criteria a, b, b safety approvals sl: ul60950, csa22.2 no.60950 slm: ul2601-1, csa c22.2 no.60601-1
17-apr-07 ac-dc 600 w 2.77 (71.0) 300 w 2.61 (67.0) input earth neutral line internal fan 600 w only remote on/off power share ac fail signal output +v+v+v -v -v -v 4.95 (127.0) 4.33 (111.0) 11.70 (300.0) 11.31 (111.0) a a a a sl & slm series mechanical details nominal output voltage (2,3) output voltage trim ovp setting typical (1) output current code 300 w 600 w 12 v 11-14 v 15.3 v 25.0 a 50.0 a 12 24 v 22-29 v 30.7 v 12.0 a 25.0 a 24 36 v 33-42 v 45.9 v 8.0 a 16.5 a 36 48 v 44-57 v 61.2 v 6.0 a 12.5 a 48 60 v 55-70 v 76.5 v 5.0 a 10.0 a 60 96 v 88-114 v 127.5 v 3.0 a 6.0 a c1 model numbering models and ratings notes 1. overvoltage protection is by the inverter shutdown method and can only be reset by disconnecting the input voltage. 2. output characteristic constant voltage - constant current type, ideal for non-linear loads. 3. other output voltages available, consult sales for details. input connectors: 0.37?(9.5mm) pitch m4 barrier block. signals: 3 x 0.04?(3 x 1.0mm) pins 1.0?(25.4mm) pitch (rof, power share and ac fail). fixings (ref ??: m3 iso metric (screws must not penetrate unit by more than 0.20?(5.0mm). notes 1. 300 w models are convection cooled. 600 w models are fan cooled. 2. not available on 12 v output. sl = standard slm = medically approved p = pfc -c = cover -d = oring diode (2) -e = conformal coating -m = ruggedisation -n = temperature compensation -t = overtemperature protection inputs outputs options example: sl 300 p s 24 - c sl = standard c = safety cover fitted 300 = power 24 = output 24 vdc s = single output p = pfc input 300 600 s = single no. of outputs power (watts) (1) style 12 = 12 v 24 = 24 v 48 = 48 v 60 = 60 v c1 = 96 v all dimensions are in inches (mm) weight: 300 w models - 3.75 lbs (1.7 kg) 600 w models - 4.19 lbs (1.9 kg)


▲Up To Search▲   

 
Price & Availability of SLM300PS12-D

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X